CE 60 Thu ursday Lab 2012 Seyoon Y Yoon
ACI Mix M Design Ex xample - Condiitions Targeted d 28-day com mpressive strrength: 4000 psi (lb/in2) Targeted d slump: 3 in Maximum m size aggreegate (MSA)): 3/8 in Cement: Type I, BSG G (Bulk Speccific Gravity y) = 3.15 Fine Agg gregate (FA)): BSG = 2.6 67, moisture = +2.37 % ((over-saturatted), finenesss modulus = 2.9 Coarse Aggregate A (C CA): BSG = 2.68, 2 moistu ure = -0.81% % (dry) dry-rod dded unit weeight (DRUW W) = 103 pcff
- Steps Step 1. Estimation E of o mixing water w and airr content baased on you ur targeted sslump and M MSA.
Therefore, the water requirementt is 385 lb/yd d3 and the reecommendedd air contentt is 3 %
Step 2. Selection S of water/cemeent ratio.
Thus, thee estimate fo or required w/c w ratio to give a 28-dayy strength off 4000 psi is 0.57
Step 5. Calculation C of cement content. c weight of cement =
385 lb/yd 3 675.44 lb//yd 3 0.57
Step 6. Estimation E of o coarse ag ggregate con ntent.
2.9 0.45
The volu ume fraction of dry-roddeed CA is 0.4 45 CA will occupy: o 0.45 5 27ft 3 /yd 3 12.15 ft 3 / yd 3 CA weig ght = 12.15 ft3/yd3 × 103 lb/ft3(DRUW W) = 1251 lb lb/yd3
Step 7. Estimation of Fine Aggregate Content Water = 385 lb / 62.4 lb/ft3
= 6.17 ft3
Cement = 675.44 lb / (3.15 × 62.4 lb/ft3) = 3.44 ft3 CA = 1251 lb / (2.68 × 62.4 lb/ft3)
= 7.483 ft3
Air = 3 % × 27 ft3
= 0.81 ft3 Total
= 17.90 ft3
Thus, FA = 27 – 17.90 = 9.1 ft3 FA weight = 9.1 ft3 × (2.67 × 62.4 lb/ft3) = 1516 lb/yd3
SSD lbs (0.01 yd3) Water = 3.85 lb
Cement = 6.75 lb
FA = 15.16 lb
Step 8. Moisture Correction FA: 15.16 + (2.37/100) × 15.16 = 15.52 lb CA: 12.51 + (-0.81/100) × 12.51 = 12.41 lb Water: 3.85 - (2.37/100)×15.16 - (-0.81/100)×12.51 = 3.58 lb Cement: 6.57 lb
CA = 12.51 lb